Datasheet: Flowline EchoPod UG01 & UG03 Reflective Ultrasonic Level Transmitter
Buy online for small quantities. For large quantities, projects and repeat business send a quotation request to: sales@birkettcontrols.com.au
The EchoPod UG01 is a general purpose reflective ultrasonic multi-function level transmitter providing continuous level measurement up to 1.5m (4.9′) with a 4–20 mA analog signal output and four relays, configured via Flowline’s free WebCal software. The non-contact liquid level sensor features Flowline’s proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions.
What sets the UG01 apart — Reflective Technology™
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact: unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45° reflector, delivering reliable level measurement.
Select this sensor for small tanks with non-foaming and mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
Both configurations feature a 2″ G (BSP) process connection and ship with a 1.2m (48″) cable. The UG01-0011-41 bundle includes the Fob USB adapter required for sensor configuration via WebCal software — ideal where on-site configuration, re-ranging, or relay programming is needed. The UG01-0011-40 is supplied without the Fob, suited to applications where configuration has already been completed or the Fob is already held on-site.
The key features are:
- Proprietary Reflective Technology™ for reliable measurement in condensing environments
- Continuous non-contact level measurement up to 1.5m (4.9′)
- 4–20 mA analog signal output, two-wire (reversible: 4–20 mA or 20–4 mA)
- Four programmable relays with embedded level control logic, configurable as:
- 1 pump or valve with 3 alarms
- 2 pumps lead-lag with 2 alarms
- 2 pumps duplexing with 2 alarms
- 4 independent switch point alarms
- Short 38mm (1.5″) dead band maximises tank filling capacity
- Narrow 50mm (2″) beam width for applications with limited space
- Corrosion resistant PVDF transducer and compact Polypropylene enclosure
- Automatic temperature compensation from –40°C to 80°C
- Fail-safe diagnostics with selectable relay and signal outputs
- Configurable signal fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
- Relay contact fail-safe: open, closed or hold last (selectable hysteresis)
- CE, RoHS compliant; UL 61010-1 approved
- Processing Magazine Breakthrough Product of the Year Award winner
Delivery time for non-stocked configurations is typically 2-4 weeks.
To order a configuration not included in the above list or for application advice, send your request to: sales@birkettcontrols.com.au or contact us for more information on 0418 325 563
Typical Application Areas:
Level measurement, switching and control of liquids for:
- Day tanks, IBC or drum, cooling towers, skid or machine installations, process tanks and waste sumps
- Chemical storage and dosing — acids, caustics, bleach, brine, chlorine, hydrogen peroxide, sodium hypochlorite and similar aggressive media
- Water and wastewater treatment
- Plating and surface treatment tanks
- Pharmaceutical, food & beverage and RO/deionised water systems
- Fertiliser, DEF and agricultural chemical tanks
Mining, industrial process and scrubber applications






Reviews